bflatasticandClaude Opus 5.5 7b30dd787b M1.9: the MCP connect-failure test holds its own closed port
remote_connect_fails_fast bound a port and dropped it, so another test or
process could take the port before the connect and make it succeed. It now
holds a socket bound without listening (socket2, a test-only dependency):
connections to it are refused and nothing else can bind it meanwhile. It
also checks the failure comes within 5 s.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>