test-msi.ps1 builds the MSI around stub binaries, validates it (ICE) and,
silently: installs into a folder with spaces and a non-ASCII name, upgrades
without naming a folder (it must stay there, one entry in Apps), repairs a
deleted file, uninstalls (files and App Paths gone), and installs to the
Program Files default. Run by a windows-latest job in packaging-lint.yml.
A fresh install opens on a destination page (Program Files by default;
Change... browses, with Up and New folder), then a Ready page that shows
the folder before anything is written. An upgrade goes straight to the
Ready page with the installed copy's folder and can't move it; opening the
MSI again offers Repair or Remove. Cancel, finish, files-in-use and error
dialogs are authored too. Silent installs (/qn) show none of it.
The dialogs (installer-ui.wxs) are original, built from Windows Installer's
own controls and events, not the WixUI library, whose MS-RL licence is not
on the allowed list. package.ps1 builds both .wxs files.
The MSI records its folder as the App Paths "Path" value of effectcraft.exe
and reads it back with a registry search, so an upgrade, a repair or a
silent reinstall goes where the installed copy already is. A folder passed
on the command line (INSTALLFOLDER=...) still wins, and INSTALLFOLDER is
Secure so a folder chosen in the UI reaches the elevated install. v0.6.0 and
earlier have no Path value and upgrade in Program Files, where they are.
Release builds add an arm64 MSI and portable zip, cross-compiled on the x64
runner (signing and WiX as for x64). package.ps1 checks each binary's PE
header before packaging: Machine must match -Arch, the app must be a GUI
program and the CLI a console program. It skips the CLI smoke run when an
ARM64 build can't run on the host. A new Windows ARM64 workflow packages the
ARM64 MSI, installs it on a Windows 11 ARM64 runner, checks both installed
exes are ARM64, runs the CLI, and uninstalls. Ported from printcraft#66.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The MSI Icon id had no .ico/.exe extension, which Windows Installer needs for
advertised shortcuts and ARPPRODUCTICON, so both showed a blank icon. Release
builds of the desktop app are now GUI-subsystem (no console window; the CLI stays
a console program), the shortcut/summary description names what EffectCraft does, and
packaging-lint rejects an Icon id without an extension. Found in printcraft#57.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>