* test(cli): pin today's command-line behaviour
The later commits change these tests on purpose, so each behaviour change shows in their diff.
* refactor(cli): split main.rs into modules, move only
- output: outln!, stdout state, atomic write, export helpers, view/window helpers
- args: USAGE, option validation, framing options, MCP argument parsing and its tests
- info, convert, sample, mcp: one subcommand each
- perf: synthetic drawing, Rng, perf subcommands
- run: run subcommand and {last} handle chaining
- main: crate docs, mod lines, install_io, open, main, cli, unit tests
No behaviour change.
* refactor(cli): typed errors and run(args, out, err)
cadcraft-cli is now a library plus a thin binary. `cadcraft_cli::run(args, out, err)
-> i32` is the whole program; main.rs only passes `args_os()` and the process
streams. Handlers write through a `Streams` wrapper (output.rs) instead of the
process streams; it keeps the closed-stdout semantics (drop later output, carry
on, a closed pipe is not an error, other write errors are reported once and make
the exit code 1). `mcp` still speaks MCP on the real stdin/stdout.
Errors are typed (thiserror): CliError (error.rs) wraps EngineError, DocError,
IoError, io::Error and the per-module WindowError, ArgsError, RunError,
OutputError and PerfError. `run` prints `error: {e}` and exits 1.
The usage text and the "unknown option/argument" messages stay as one
transitional CliError::Usage(String), printed without the `error: ` prefix.
USAGE stays a const; step 4 (clap) removes both. The engine's IoHooks take
`Result<_, String>`, so the three `.map_err(|e| e.to_string())` in install_io
remain. The hooks are set-once (OnceLock), so installing them on every `run`
call is harmless.
tests/it/usage.rs calls `run` in-process with Vec<u8> writers; the headless mcp
case runs through the binary (it reads the real stdin) and a non-Unicode
argument test is new.
Behaviour changes (old -> new):
- Every error line other than the usage-class ones gains the prefix `error: `
(e.g. `--view needs ...` -> `error: --view needs ...`, `unknown command
`x`` -> `error: unknown command `x``, `invalid parameters for `open`: ...`
-> `error: invalid parameters ...`, `unsupported file type` likewise).
- `cadcraft-cli: cannot connect to HOST:PORT: e` -> `error: cannot connect to
HOST:PORT: e` (the old prefix is replaced).
- A non-Unicode argument: panic, exit 101 -> `error: argument "..." is not
valid Unicode`, exit 1.
- Unchanged: usage text, `X: unknown option --y`, `unknown option --y`,
`mcp: unknown argument ...` (no prefix); warnings and `wrote ...` lines;
the `cadcraft-cli: can't write to stdout: e` report; exit codes.
* refactor(cli): parse arguments with clap
Replace the hand-written parser (USAGE, validate_options, OptionSpec,
framing_option, parse_mcp_args, CliError::Usage) with clap derive types
in args.rs: a Cli parser and one Args struct per subcommand, with the
framing flags (--window, --view) in a FramingArgs struct flattened into
convert and run. USAGE's framing and --cmd chaining text moves into the
subcommands' and flags' doc comments and run's long help, so --help
carries it. `commands` moves from an inline closure to commands.rs.
`command()` exposes the clap definition for man pages and completions.
clap reads the arguments as OsStrings. Help and --version go to stdout
with exit 0; usage errors are clap's, on stderr with exit 2. A bare
--help or -h before `--` shows the subcommand's help even after a
mistake on the line (`run --script --help`). run opens its drawings
(FILEs, --sample, --metric) and runs its steps (--script, --script-file,
--cmd) in command-line order, from ArgMatches::indices_of. Values stay
strings checked by the handlers, with their messages and exit 1
(--window, --view, --cmd JSON, sample names, perf counts). The last of a
repeated flag wins (args_override_self on every subcommand but mcp).
Behaviour changes:
Help and version
- --help, -h, help: the USAGE page -> clap's help, first line
"cadcraft-cli: headless CADCraft".
- bare cadcraft-cli: USAGE on stderr, exit 1 -> clap's help on stderr,
exit 2.
- <subcommand> --help / -h, help <subcommand>: "unknown option --help"
(exit 1), the USAGE page (convert, help <subcommand>) or a file named
-h (info -h, run -h) -> that subcommand's help, stdout, exit 0.
- <subcommand> --version: "unknown option --version", exit 1 -> clap's
unexpected argument, exit 2.
Usage errors (exit 1 -> exit 2, clap's messages)
- Unknown subcommand, empty subcommand, unknown top-level flag: USAGE ->
"error: unrecognized subcommand 'foo'" / "error: unexpected argument
'--bogus' found".
- Unknown flag on any subcommand: "info: unknown option --bogus",
"unknown option --bogus", "mcp: unknown argument --bogus" or USAGE
(convert) -> "error: unexpected argument '--bogus' found".
- A short flag where a file is expected (info -x): opened as a file ->
unexpected argument; `--` before it keeps it a file name.
- A value flag at the end or followed by a flag (--window, --view,
--script, --script-file, --cmd, --save, --export, --connect): "error:
--script needs text" and the like, or the next flag taken as the
value (--window --view, --script --sample, --cmd --sample,
--script-file --sample) -> "error: a value is required for '--script
<TEXT>' but none was supplied". --connect followed by an unknown flag
(--connect --foo, --connect -v) names that flag instead (clap reports
the unknown argument, not the missing value).
- mcp --connect with an empty value: "error: --connect needs HOST:PORT
..." -> "error: invalid value ' ' for '--connect <HOST:PORT>':
expected HOST:PORT (...)"; --connect=-v likewise.
- mcp --connect twice: "error: --connect given more than once" ->
"error: the argument '--connect <HOST:PORT>' cannot be used multiple
times".
- mcp --lazy / --launch without --connect: "error: --lazy and --launch
need --connect HOST:PORT" -> "error: the following required arguments
were not provided: --connect <HOST:PORT>".
- Missing positionals (info, convert with 0 or 1 files, sample with 0
or 1 arguments): USAGE -> "error: the following required arguments
were not provided".
- Extra positionals: convert with three files (USAGE), and info,
commands, perf, sample, which ignored the extra argument -> "error:
unexpected argument 'extra' found".
- perf -5: opened as a file -> unexpected argument '-5'.
- A non-Unicode argument where text is expected: "error: argument ... is
not valid Unicode", exit 1 -> "error: invalid UTF-8 was detected in
one or more arguments", exit 2.
Accepted where they were errors
- --x=v is a spelling of --x v for every value flag (--window, --view,
--script, --script-file, --cmd, --save, --export, --connect); before
it was an unknown option or USAGE. A value starting with - needs the
= form (--cmd=-x).
- commands --: "unknown option --" -> `--` ends the options (all
commands listed).
- run --view extents --view current: "use only one of --window and
--view" -> the last wins, like every other repeat.
Other
- run --sample --sample opens one sample drawing (was two): repeated
flags are last-wins.
- run checks --window/--view values before opening any drawing, so a
bad framing value is reported ahead of a missing file.
- `-h` after a mistake shows the long help (`--help`): the retry asks
for --help.
Unchanged: --window with --view, framing without an image output,
--view's case-insensitivity, all value messages (--window numbers,
--view values, --cmd JSON, {last}, sample names, --script-file read
errors), multiple FILEs, --sample with --metric or a FILE, last-wins
for --save, --export, --window, --script/--cmd order, and `\n` in
--script.
clap forced: exit 2 for usage errors, its message wording, and the
unknown-flag-over-missing-value precedence above.
* refactor(cli): reject repeated flags, long version (photocraft#7071 decisions)
Behaviour changes, old -> new:
- --save, --export, --window, --view, --sample, --metric, --lazy, --launch given twice:
last one won -> usage error, exit 2 ("the argument ... cannot be used multiple times").
--connect was already rejected. --script, --script-file, --cmd and run's FILEs still repeat.
- --version / -V: "cadcraft-cli <version>" -> "cadcraft-cli <version> (<sha>)", sha from
CADCRAFT_BUILD_SHA or "dev", as the desktop app prints it.
- "cadcraft-cli version" is an unrecognized-subcommand usage error (as before; now tested).
- A value starting with "-" needs the = form for every value flag (as before, tested).
--window -10,-10,10,10 stays a usage error ("unexpected argument -1"); write
--window=-10,-10,10,10. clap's allow_negative_numbers does not accept a comma list, and
allow_hyphen_values would let --window swallow the next flag, so neither is set. The
--window help text names the = form.
* refactor(cli): typed values and flag relations
Step 6 of #2228: values are parsed into their types and flag relations
are checked at parse time, so a bad value or combination is a usage
error (exit 2) naming the flag, before any work starts. The handlers
receive typed values only. Runtime failures (files, the engine, a
`{last}` with no earlier handle) stay exit 1.
- --window parses to a Bounds2 (parse_window plus cadcraft_io's
check_window); its WindowError is the value parser's error.
- --view is a ValueEnum (extents, current), case-insensitive; the long
help lists what each value does.
- --window conflicts_with --view. In run, --window/--view require
--export (an ArgGroup "framing" with requires). A framing flag with
an output that isn't an image (convert's OUT, run's --export) is a
UsageError turned into a clap error by into_clap (ArgumentConflict).
- sample's name is a ValueEnum (bracket, floorplan); `floor` stays a
hidden alias.
- perf's N|FILE is one typed positional: a value that parses as a
count is one, clamped to 1..=20000000 as before (so `perf 0` still
times one entity); anything else is a drawing.
- --cmd 'id {json}' parses to an id and a serde_json::Value (default
{}); `{last}` is still filled in when the command runs.
- Paths are PathBufs (info FILE, convert IN/OUT, run FILEs,
--script-file, --save, --export, sample OUT, perf FILE). The engine
and io crates take file names as text, so a path that isn't valid
Unicode is refused by the handler, naming the file (exit 1).
- Deleted: check_framed_output, the --view match, ArgsError,
CliError::Window/Args/UnknownSample, RunError::CmdJson,
PerfError::BadCount.
- run's FILEs, --sample and --metric still combine (each opens another
drawing, the last is current): neither photocraft#7071 nor RFC-0012 requires
otherwise.
Behaviour changes (old -> new):
- --window with a bad value (wrong count, not a number, NaN/inf,
reversed corners, beyond 1e12): exit 1 `error: --window ...` ->
exit 2 `error: invalid value 'V' for '--window <x0,y0,x1,y1>':
<reason>`. The reasons no longer repeat the flag or the value.
- --view with a bad value: exit 1 `error: --view needs `extents` or
`current`` -> exit 2 `error: invalid value 'V' for '--view
<extents|current>'` plus clap's possible-values line.
- --window with --view: exit 1 `error: use only one of --window and
--view` -> exit 2 `error: the argument '--window <x0,y0,x1,y1>'
cannot be used with '--view <extents|current>'`.
- run --window/--view without --export: exit 1 `error: --window/--view
need an image output ...` -> exit 2 `error: the following required
arguments were not provided: --export <OUT.png>`.
- A framing flag with a non-image output: exit 1 `error:
--window/--view only apply to image output (png, svg, pdf), not
`OUT`` -> exit 2 `error: --window only applies to image output (png,
svg, pdf), not `OUT`` (or --view: the message names the flag given).
- sample with an unknown name: exit 1 `error: unknown sample `X`
(bracket, floorplan)` -> exit 2 `error: invalid value 'X' for
'<bracket|floorplan>'` plus the possible values. sample's help lists
the possible values.
- --cmd with JSON that doesn't parse: exit 1 `error: --cmd ID:
<serde error>`, after the earlier steps ran -> exit 2 `error: invalid
value 'V' for '--cmd <id {json}>': <serde error>`, before anything
runs.
- --cmd with an empty id (`--cmd=` or `--cmd ' {}'`): exit 1 `error:
unknown command `` ` -> exit 2 `... expected a command id, then
optionally its JSON parameters`.
- An empty path argument (info "", sample bracket "", perf "", ...):
exit 1 from the engine or io -> exit 2 `error: a value is required
for '<FILE>' but none was supplied` (clap's PathBuf parser).
- A path that isn't valid Unicode: exit 2 `error: invalid UTF-8 was
detected ...` -> exit 1 `error: PATH: the file name is not valid
Unicode` (text values that aren't Unicode stay exit 2). A non-Unicode
--save or --export is refused before any drawing opens.
- perf's help gives the count range.
Tests: usage.rs rows above moved to exit 2 with clap's messages; new
rows for --view with a non-image output, run's framing with a dxf
--export, an empty --cmd id, bad --cmd JSON after a good step, a
`{last}` with no earlier handle, --window beyond 1e12, case-sensitive
sample names and empty paths. The non-Unicode test covers both a path
(exit 1) and text (exit 2). Unit tests: the --window parser tests moved
to args.rs; new ones for --cmd values and perf targets; framing_options
checks the clap error kinds.
* refactor(cadcraft): move launch-argument parsing into launch_args
Moves the hand-written parser (the argument loop, control_port_from, control_flag and their tests) from main.rs into launch_args.rs, which returns LaunchArgs. No behaviour change.
* refactor(cadcraft): parse launch flags with clap (RFC-0012)
Replaces the hand-written loop in launch_args.rs with clap derive types, as photocraft's launch_args.rs does. --help is generated from the doc comments and lists the other CADCRAFT_* variables.
Behaviour changes (old -> new):
- An unknown flag (--sampel) was opened as a file; it is now a usage error on stderr, exit 2, before the window opens. A file starting with "-" goes after "--".
- A repeated --control or --sample was accepted (last wins); it is now exit 2.
- A bad port (--control abc, 70000, -1) was logged and the control channel left off; it is now exit 2. The same for CADCRAFT_CONTROL_PORT, and the error names the variable when the value came from it.
- A bare --control (no value) kept CADCRAFT_CONTROL_PORT's port with a warning; it is now exit 2 ("a value is required"). A following flag is never taken as the value.
- An empty or blank CADCRAFT_CONTROL_PORT was logged as a bad port; it is now unset.
- --control=7979 is accepted (the equals form was opened as a file before).
- --version / -V and --help stop parsing at once and exit 0; version text is unchanged ("cadcraft <version> (<sha>)").
- -psn_* (Finder process serial number) is dropped instead of opened as a file.
- A file name that is not valid Unicode used to panic in std::env::args(); it is now read from args_os and reported with a log warning, not opened, because CadApp::open_path takes text.
Copied from photocraft's crates/automation/src/args.rs: blank_env_is_unset and name_env_vars unchanged (name_env_vars gets a local use for ContextKind/ContextValue); control_port and NotAPort unchanged. allow_negative_numbers is set on --control as in photocraft, so -1 is a bad value rather than a missing one.
* feat(cli): shell completions and man pages
Adds examples/man-and-completions.rs, which writes cadcraft-cli's bash, zsh, fish, elvish and
PowerShell completions (clap_complete) and man pages (clap_mangen: cadcraft-cli.1 and one per
subcommand) into a directory. clap_complete and clap_mangen are dev-dependencies, so the binary
is unchanged.
packaging/linux/package.sh builds the example in its own cargo run, runs it (through $EMULATOR
for cross builds; warns and leaves the files out without one) and installs the man pages and the
bash, zsh and fish completions into the staged tree. nfpm.yaml already ships the whole
usr/share tree, so it needs no change.
CADCraft has no FreeBSD packaging, so there is no FreeBSD script to update. macOS and Windows
packaging are untouched.
tests/man_and_completions.rs checks the generated file names.
* ci(cli): check the command-line code with ast-grep (RFC-0012)
Adds ast-grep rules from RFC-0012, run by craft-common-actions'
reusable ast-grep workflow (Linux, no Rust build, path-filtered):
- clap-error-message: a string literal, format!, .to_string() or
SCREAMING_CASE const passed to Command::error / Error::raw
- clap-error-message-variable: the same message built into a variable
first, in the same function
- string-error: Result<_, String>, Err(format!(..)), Err(".."),
Err(x.to_string())
- args-os: std::env::args(), which panics on non-Unicode arguments
Scan paths: apps/cadcraft-cli/src, apps/cadcraft/src/launch_args.rs,
apps/cadcraft/src/main.rs. Rule tests run first in CI.
Source: photocraft#9750 at d16686cd. Only the scan paths and the
workflow path filters differ from it.
Fixes: none needed. The rule tests pass (4 passed) and the scan finds
nothing in the scanned paths.
* docs(cli): cadcraft-cli page, following RFC-0012
docs/cli.md: --help is the reference; exit codes, streams, usage
errors, values starting with -, paths, completions and man pages; the
environment variables (none for cadcraft-cli, CADCRAFT_CONTROL_PORT for
the desktop app's --control); and the rules not followed yet, with the
reason. The README links it.
* feat(cli): refuse an output that replaces an input
RFC-0012 rule 1.6: nothing destructive by default.
Behaviour change: `convert a.dxf a.dxf`, `run a.dxf … --save a.dxf` and
`run a.dxf … --export a.dxf` used to overwrite the input. They are now a
usage error (exit 2, `error: …` on stderr, nothing opened or written)
unless `--in-place` is given. "Same file" is file identity (same-file
crate), so `dir/./a.dxf` and a symlink to the input count. An output
that does not exist, or a failed identity check, is not refused; the
open or write reports the real error. Replacing an existing file that
is not an input is still allowed.
Scope: `--save` and `--export` only. A save that a --cmd or script runs
(for example `saveas`) is the engine's and is not checked.
Every write the CLI makes (convert OUT, --save, --export, sample OUT) resolves
an existing output first, so writing through a symlink updates the file it
points to and the link stays a link; the atomic rename used to replace the
link with a regular file, leaving the target (with --in-place, the input)
unchanged.
* feat(cli): --compact for JSON output
RFC-0012 rule 1.3: info and commands pretty-print their JSON by
default; --compact prints it on one line. run prints one JSON line per
--cmd result (JSON lines, one result per step), as its help and the
README document, so it takes no --compact. mcp's stdout is the MCP
protocol and is unchanged.
Behaviour change: info and commands accept --compact (it was an
unknown flag, exit 2). Their default output is unchanged.
docs/cli.md says which subcommand prints which form, and lists perf's
text table (no --json) and saves a --cmd or script runs (not checked
by --in-place) under "Not followed yet".
* fix(cadcraft): one Switch parser for boolean environment switches
CADCRAFT_VSYNC, CADCRAFT_SYSTEM_CURSOR, CADCRAFT_WAYLAND and
CADCRAFT_NO_NATIVE_MENU each had their own idea of "on". They now share
cadcraft_ui_egui::switch::Switch: 1/on/true/yes is On, 0/off/false/no is
Off (case- and space-insensitive), unset or blank is Default, and any
other value is Default and logged with the variable name. The ENVIRONMENT
help text says the same for all four.
Behaviour changes (old -> new):
- CADCRAFT_WAYLAND=0 counted as on (any value did); now only On keeps
native Wayland.
- CADCRAFT_NO_NATIVE_MENU=0 counted as on (any value did); now only On
keeps the menus inside the window.
- CADCRAFT_SYSTEM_CURSOR treated every value except ""/0/false/off as on;
now only the On spellings do, and an unknown value is logged.
- CADCRAFT_VSYNC is unchanged except that an unknown value is logged.
* fix(cli): keep paths as paths until a file is opened
A path is now text only where text is needed.
- cadcraft: FileNames.unreadable is Vec<PathBuf>, logged with {:?}
(escaped bytes) instead of a lossy rendering.
- cadcraft-cli: unicode() is called only inside open(), the one place
that sends a path to the engine as JSON. convert, sample and run
--save/--export pass the output as &Path. write_atomic, export,
export_framed and OutputError::Write take or hold a Path/PathBuf;
errors use .display(), and the `wrote ...` line uses .display().
- Dropped the dead find_subcommand lookup in launch_args (LaunchArgs has
no subcommands).
- docs/cli.md: non-Unicode names are refused only where a drawing is
opened.
Behaviour change: an output name that is not valid Unicode used to be
refused (exit 1); it is now written under that exact name. Opening such
a drawing is still refused.
Lossy strings that remain (all feed APIs that take text and only look at
the extension, never at the path the bytes are written to):
- cadcraft_io::write / write_framed (name picks the format) in sample.rs
and output.rs::export_framed;
- cadcraft_io::is_image in convert.rs, run.rs and args.rs (framing flag
check);
- cadcraft_engine::cmd::file::drops_unknown in export_framed.
These go away when cadcraft_io and the engine take impl AsRef<Path>
(the A1 follow-up). A non-Unicode extension is not a known format either
way, so it is rejected as an unsupported type, as before.
* refactor(cadcraft): read the environment once into Env
The desktop app reads its CADCRAFT_* variables once at startup into
apps/cadcraft/src/env.rs `Env` and passes the values on; no library crate
reads a CADCRAFT_* variable at run time any more.
- One `VARS` table (name, help line) feeds both the reader and the
Environment section of `cadcraft --help`. A test checks that every
variable the reader asks for is in the table, that every table entry
sets a field, and that the help lists every entry.
- vsync goes to `gpu::surface_config`, the system cursor to
`CadApp::set_system_cursor_default` (Options reset and Reset Palettes go
back to it), FONTALT/FONTFALLBACK to the `cadcraft_fonts::ttf` setters
(re-exported as `cadcraft_engine::fonts`), the settings directory to the
new `cadcraft_engine::settings_dir::set`, and to `Workspace::load`.
- The three copies of the settings-directory rule (main.rs, workspace.rs,
the engine's plotter folder) are one: `settings_dir::platform`.
- `Switch::from_env` is gone; `Switch::parse` stays.
- The child-process tests for CADCRAFT_CONTROL_PORT are replaced by tests
that inject the variable lookup (`blank_env_is_unset`) or point
`--control`'s fallback at PATH.
cadcraft-cli: plotter configurations matter to its output (`run --cmd plot`
or a script's PLOT with a user device, and the same through `mcp`), and the
font variables change how convert/run/sample draw text. So, following
RFC-0012 rule 1.7, the variables become fallbacks of flags declared with
`env =`: --config-dir (CADCRAFT_CONFIG_DIR), --fontalt (CADCRAFT_FONTALT)
and --fontfallback (CADCRAFT_FONTFALLBACK) on convert, run, mcp and sample.
Behaviour changes:
- CADCRAFT_CONFIG_DIR set but empty counts as unset everywhere: the
workspace file and the plotter folder use the platform folder (was:
workspace persistence and the plotter folder off). Logs and autosave
already treated it so.
- The workspace file and the plotter folder ignore a relative
XDG_CONFIG_HOME, as logs and autosave did (was: used it).
- A blank CADCRAFT_LOCALE means the system's languages (was: [""]).
- cadcraft-cli: the three variables apply only to convert, run, mcp and
sample, as flag fallbacks (was: read by the engine and fonts in every
subcommand, perf included). A font variable that isn't valid Unicode is
a usage error naming the flag (was: ignored).
* refactor(io): one Format enum for file extensions
`cadcraft_doc::Format` (re-exported as `cadcraft_io::Format`) is the one
place that maps a file name's extension to a format: Dxf, Dwg, Dwt, Svg,
Svgz, Png, Pdf. `from_path` is ASCII case-insensitive; no extension (or a
trailing dot) is Dxf; an unknown extension is None. `READ` and `WRITE`
list the formats `read` and `write` accept. It lives in cadcraft-doc
because the engine depends on cadcraft-io only for tests.
Each place used to match on its own lower-cased extension string and now
matches on Format, with the same results:
- io::read: svg/svgz -> SVG reader, dxf/none -> DXF reader, other ->
try DXF, else Unsupported(ext).
- io::write_with: dxf/none -> DXF, dwg -> DWG bridge, other with binary
-> error, rest -> write_framed.
- io::write_framed: dwt -> DWG; dxf/none/dwg -> write_with; svg, png,
pdf -> image writers; other -> Unsupported(ext).
- io::is_image: svg, png, pdf (not svgz, which is read only).
- engine file.rs is_dxf, drops_unknown (dwg, dwt), is_drawing_file
(dxf, dwg, dwt, none).
Behaviour change (help text only): the CLI help lists the formats from
Format::READ / Format::WRITE instead of hand-written lists. `info` and
`convert IN` now name svg and svgz as readable, and `convert`, `sample`,
`run --save` and `run --export` name dwt (and `sample` pdf) as writable.
A test checks each file argument's help names every format of its list.
* refactor: one version string for the app and the CLI
cadcraft_engine::build_version() builds "<version> (<commit>)" once; the
desktop app's --version, its start-up log line and cadcraft-cli --version
all use it. No change in output.
* refactor(cli): share the environment helpers with the CLI
Move blank_env_is_unset and name_env_vars from the desktop app into
cadcraft_mcp::args and apply them in the CLI parser.
Behaviour changes (old -> new):
- Empty or blank CADCRAFT_FONTALT / CADCRAFT_FONTFALLBACK: reached clap as
Some("") -> counts as unset.
- A bad value from an environment variable: the error named the flag ->
names the variable.
- CADCRAFT_CONFIG_DIR is unchanged: empty still means no settings folder.
- Desktop app: unchanged; it uses the shared helpers.
* refactor: pass paths, not text, through io, engine and open_path
cadcraft_io::{read, write, write_with, write_framed, is_image}, the engine's
drops_unknown/is_drawing_file/read_text_file and CadApp::open_path take
paths (impl AsRef<Path> / &Path). The desktop launch arguments and the CLI
no longer convert paths to text to call them.
Behaviour changes (old -> new):
- A dropped file whose name is not valid Unicode opened with a "can't
read" error naming a mangled path; it now opens natively. (Its path is
not remembered for QSAVE, which then asks where to save.)
- A launch argument that is not valid Unicode was logged and skipped; it
now opens like any other.
- A .dwt export builds the .dwg name as a path, not formatted text.
- On the web, a non-Unicode path passed to open_path reports "the path
is not valid Unicode" instead of a lossy name.
- Opening errors print path.display().
FileNames and LaunchArgs::file_names are removed; the launch tests assert
the parsed PathBufs. New io test: non-Unicode names pick the format by
extension.
* docs(cli): CADCRAFT_CONFIG_DIR is the one flag fallback where empty isn't unset
* fix(engine): refuse a drawing path that isn't valid Unicode
read_file opened such a path with no saved path, so QSAVE could not save back to it.
It now returns an open error naming the file before reading it. The ui-egui opener
already reports read_file errors like any other failed open.
* fix(cli): report a failed write of help or version
A write error on help or version output (other than a closed pipe) now exits 1 and
tries to say so on stderr; it was ignored and exited with the clap code. A closed pipe
keeps the clap exit code.
* fix(cli): --connect needs HOST:PORT
--connect example.com was accepted and failed later. It is now a usage error (exit 2)
unless the value is a non-empty host (or a bracketed IPv6 address) and a u16 port.
The host is not resolved.
* docs(cli): run prints no line for a command with no result
* refactor(cli): explicit imports and smaller functions for the stricter lints
Lints: clippy::wildcard_imports, too_many_arguments, cognitive_complexity (30).
Replaced the non-test `use super::*;` in args, commands, convert, info,
output, perf and run with explicit imports; lib.rs keeps only the imports
its non-test code uses, and its test module imports the rest itself. The
`super::*` in the test modules stays.
A clippy run with all three lints and threshold 30 reports nothing in
apps/cadcraft-cli or in code this branch added, so no function needed
splitting.
16 KiB
CADCraft control protocol
Start the desktop app with --control PORT (or CADCRAFT_CONTROL_PORT=PORT). It listens on
127.0.0.1:PORT for JSON lines: one request per line, one reply per line. A port given with
--control wins over the variable; a bare --control keeps the variable's port.
{"id": 1, "method": "cmdline.input", "params": {"text": "circle 0,0 5"}, "token": "<session token>"}
{"id": 1, "ok": true, "result": {"prompt": "Command:", "output": ["Command: CIRCLE"], ...}}
Every request must carry the session token. Because loopback TCP cannot tell local operating
system users apart, the app writes an unguessable per-session token to an owner-only file when the
control server starts, and refuses (unauthorized) any request without a matching token. The file
is cadcraft-control-<port>.token in the per-user runtime directory ($XDG_RUNTIME_DIR, else
~/.cache; %LOCALAPPDATA% on Windows); its path is logged at startup. A client reads the token
from that file — which requires the desktop user's own filesystem access — and includes it on each
line. The MCP bridge (cadcraft-cli mcp --connect) does this automatically.
Errors come back as {"id": …, "ok": false, "error": "message"}. An unknown method's error points
to control.methods, which lists the methods the server answers.
A line that is not a JSON object with a string method (an HTTP request, text that isn't JSON,
bytes that aren't UTF-8) gets one error reply and the server closes the connection; nothing sent
after it runs. Blank lines are skipped.
The server bounds what a client can hold: 16 connections at once (more get an error line and are
closed), 256 MiB per request line (longer closes the connection), 64 queued requests (more are
answered {"ok": false, "error": "busy: …", "state": "not-run"}), and 10 minutes idle or 30 seconds
per blocked reply write before the socket is closed.
The server waits up to 60 s for the app to answer a request. After that it replies with a timeout, and
state tells whether sending the request again is safe:
{"id": …, "ok": false, "error": "timeout", "state": "not-run"}: the app had not started the request. It is cancelled and will never run, so sending it again is safe.{"id": …, "ok": false, "error": "timeout", "state": "may-have-run"}: the app had already started it. It may still finish and change the drawing, and its late result is discarded. Inspect the drawing (drawing.inspect) before sending it again.
The table below describes top-level control-protocol methods: names for the request's method
field. engine.commands returns a separate command catalog, not a list of additional methods.
| Method | Params | What it does |
|---|---|---|
cmdline.input |
{text} |
Type a line at the command line exactly like a user. Starts commands by name/alias and answers prompts (points x,y, @dx,dy, @d<a, distances, keywords, empty = Enter). Spaces act as Enter except at text prompts. |
cmdline.script |
{text} |
Run a multi-line script (like .scr files). |
cmdline.key |
{key: "enter"|"escape"} |
Press Enter or Escape. Replies like cmdline.input: the state, output, and error when Enter was refused. |
cmdline.state |
Current prompt, keywords, accepted input kinds, history tail. | |
engine.execute |
{command, params} |
Run any command with JSON parameters. Never opens a dialog. command is an alias of this method, with the same parameters and result. |
engine.commands |
Every command: id, label, menu path, shortcut, aliases, params doc, enabled. | |
drawing.inspect |
{entities?, limit?} |
Drawing summary (counts, extents, layers, styles, blocks, layouts, selection, undo) and entities with handles and geometry. |
ui.inspect |
UI state, canvas rect, view, cursor and snap, performance counters (uiFrames, passIndex included); closePrompt: the drawing a "Save changes?" prompt is asking about (null when none); and actual egui keyboard focus (focus.id, focus.label, focus.role). |
|
ui.elements |
{label?, role?, focused?} |
Observed toolbar, tab, drafting and layer-palette controls from the latest UI frame. Filters match exactly. Each entry has its real egui id, label, role, rectangle [x,y,width,height], enabled/visible/selected state and current focus. |
ui.menu.list / ui.menu.invoke |
{command} |
The menu tree; invoke an item like a click (interactive). |
ui.pointer |
{x, y, space?: "world"|"screen", button?, action?: "click"|"move"} |
Click in the drawing area (world coordinates by default). Right button = Enter. |
ui.click / ui.move |
{x, y, button?, shift?, ctrl?} |
Real egui pointer events in screen points (reach every widget). |
ui.drag |
{x, y, to: [x, y], button?} |
Real press, move and release (drag the command line's top edge, the ViewCube ring…). |
ui.key / ui.text |
{key, cmd?, shift?, alt?} / {text} |
Synthetic keyboard input. |
ui.set |
UiState fields | Show/hide palettes, toolbars, command line, ViewCube…; theme: "system"|"light"|"dark" (also engine.execute with ui.theme {theme}); ui.inspect reports the theme shown (theme: light/dark). animations: "system"|"on"|"off" (also ui.animations {animations}) shows or hides animation effects (dialog and menu fades, smoothed scrolling), system following the operating system's setting; ui.inspect reports whether they show (animations: true/false). saveFormat: "dxf"|"dwg" (also ui.saveformat {format}) is the format Save As suggests for new drawings; saveVersion: "2000"…"2018" (also ui.saveversion {version}) the version it saves them in (SAVEAS also takes version and binary directly). |
ui.resize |
{width, height} |
Resize the window. |
ui.focus |
Activate the native window. Does not assign focus to a widget. | |
ui.screenshot |
{path?} |
PNG of the window (needs a presented frame). Bounded: at most 4 queued/in-flight/completed requests, 64 MiB per image and 64 MiB total (completed but undrained images still count), an 8 s deadline, and cancellation when the document or keyboard focus changes while the request is outstanding. A queued request adopts the settled window size when issued. After issue, a change in window size, scale, OS window focus, minimization or occlusion cancels it. Every reply carries request; failures include ok:false,error. Files are written only after the deadline and identity checks pass. Without path, each request gets a unique PNG in a private owner-only per-process directory under the temp dir (created exclusively; an existing symlink is never followed), so concurrent app instances cannot collide; the caller owns those files and should remove them when done. |
ui.render |
{path?, width?, height?, fit?} |
Headless render. fit (default true) frames the whole drawing; false uses the current view. Replies {pngBase64, width, height, bytes, path?}. |
app.open / app.save / app.quit |
{path} |
File operations. |
control.methods |
Every method this server answers: {method, params, description}. Headless (cadcraft-cli mcp) lists only the methods it serves. |
|
ping |
Replies "pong". A cheap health check. |
To run a command listed by engine.commands, put its id in params.command and its arguments
in the nested params.params object, using engine.execute as the top-level method. This
includes open and document.bytes, and the UI commands in the desktop app's catalog.
drawing.inspect is also an engine command, but has an explicit top-level method; a dotted
command id alone does not make it a protocol method.
For example, inspect the drawing and list commands directly, then open a drawing and get its
DXF bytes through engine.execute (one request per line):
{"id":2,"method":"drawing.inspect","params":{}}
{"id":3,"method":"engine.commands","params":{}}
{"id":4,"method":"engine.execute","params":{"command":"open","params":{"path":"examples/apartment.dxf"}}}
{"id":5,"method":"engine.execute","params":{"command":"document.bytes","params":{}}}
The open example assumes the app was started from the repository root; otherwise use a path
to an existing drawing accessible to the app. document.bytes defaults to DXF and returns
base64-encoded bytes in the result's data field. The command alias can be used identically:
{"id":6,"method":"command","params":{"command":"document.bytes","params":{}}}
Sending open or document.bytes as the top-level method returns an unknown method error:
the protocol dispatches methods explicitly and does not fall through to the command registry.
app.open is a top-level convenience method for opening a drawing with {path}.
To read selected objects as structured geometry in a single query, execute entities with
selected: true (a boolean; omitted/false keeps the unfiltered selection behavior):
{"id":7,"method":"engine.execute","params":{"command":"entities","params":{"selected":true,"limit":1000}}}
Only selected entities in the active space are returned; an empty selection returns an empty
page. The selection filter combines with type, layer and window before offset/limit.
The existing response is unchanged: count is all matches, returned is the page size and
entities contains handles, layers and geometry. This query does not change selection, drawing
contents or undo history. entities is a command, not a top-level protocol method.
The MCP server (cadcraft-cli mcp --connect 127.0.0.1:PORT) wraps this protocol; headless
(cadcraft-cli mcp) it serves the same methods from an in-process session.
MCP tool names are another interface: execute maps to engine.execute, list_commands to
engine.commands, and the MCP open tool to app.open. See mcp.md.
ui.key queues real egui key events; its reply acknowledges the queue. Poll ui.inspect or
ui.elements for the resulting focus or state before sending the next action. Use Tab and
Shift-Tab to traverse controls and Enter/Space to activate them. The observed registry is not
the operating system's accessibility tree and does not establish physical input or screen-reader
acceptance. Unregistered controls still report their actual focus ID, with a null label/role.
The native host restores layout choices from workspace.json and saves changes atomically.
It stores palette/toolset visibility, selected toolset, collapsed groups, command-line history
height and related chrome choices. It does not store drawings, command buffers, dialogs or the
current Start tab. The default directory is ~/Library/Application Support/CADCraft on macOS,
%APPDATA%/CADCraft on Windows, and $XDG_CONFIG_HOME/cadcraft or ~/.config/cadcraft elsewhere.
Set CADCRAFT_CONFIG_DIR to a private directory for an isolated profile; an explicitly empty
value disables all settings reads and writes (workspace, logs, autosave, plotters). An invalid, oversized or newer-version file is
reported and left untouched, with persistence disabled for that launch. Repair or move that
file before restarting to resume saving workspace choices.
Panel docking
Tool Sets, Layers, and Properties can be regrouped, split, floated within the app window, closed, and reopened. The drawing canvas stays visible and cannot be closed or turned into a tab. The document/session view is protected. Layouts, active tabs, panel visibility, and floating rectangles are saved with the app's existing UI preferences. These operations do not edit document contents.
Panel IDs: toolSets, layers, properties, externalReferences. The protected center is canvas.
ui.dock accepts operation; basic per-panel operations also require panel. The advanced resizeSplit operation below uses a split path instead of a panel. Basic operations are open, close, activate, float (with finite positive rect: [x, y, width, height]), or move (with target and zone: center|tab|left|right|top|bottom|above|below, default center). Center and tab group with the target; side zones split beside it; above and below add a group in a floating window. open and activate show a hidden panel at its last place and select it. ui.dock.reset restores the default arrangement. Invalid moves return an error without changing the layout.
The QuickCalc palette (quickCalc) is not part of the default arrangement. Typed QUICKCALC/QC
and ui.panel.quickcalc explicitly open and activate it: it floats the first time and later
reopens at its saved location. Window > QuickCalc and Ctrl/Cmd+8 invoke
ui.toggle.quickcalc instead, closing the panel when present and reopening it otherwise.
The shortcut also works with text-field focus. Toggling preserves the running drawing command
and pending command-line input. The expression, history and calculator variables survive
closing/reopening within the same session; they are not saved across application restarts.
Invoke these UI commands through engine.execute, for example {"command":"ui.dock","params":{"operation":"float","panel":"layers","rect":[100,100,320,440]}}.
Advanced ui.dock operations use the same validated transaction as pointer gestures:
moveFloating updates rect, resizeSplit accepts a boolean child path and
size ({"Ratio":0.5}, {"FixedFirst":280}, or {"FixedSecond":280}),
setStackOpen takes open, and resizeStack takes a point height or null.
A center or tab move can include before (panel ID or null to append) for tab order.
The equivalent {"action": ...} form accepts a serialized shared docking action;
this is also the form emitted by the renderer, and it takes every action of craft-ui's docking, group, column and window moves included. Protected-canvas and app-specific panel
rules apply equally to both forms.
Command-line replies
The app and the headless session reply with the same fields.
cmdline.state, cmdline.key and cmdline.input return the command-line state:
| Field | Value |
|---|---|
prompt |
The prompt text ("Command:" when idle). |
running |
The id of the running command, or null. |
keywords |
The current prompt's options. |
accept |
The kinds of input the current prompt accepts, or null when idle. |
buffer |
Text typed in the command line but not yet submitted (always "" headless). |
history |
The last 20 history lines. |
historyExpanded |
Whether the history is expanded (always false headless). |
cmdline.input adds:
output: the history lines the input added. This includes the error message when the line was refused.error: the error message, only when the line was refused (unknown command, invalid input…).
A refused line still replies "ok": true, because the text was typed. Check error.
app.open without a string path fails with "missing path" before any command runs.
Interface language
Select a language with engine.execute and the UI command ui.language:
{"id":1,"method":"engine.execute","params":{"command":"ui.language","params":{"lang":"uk"}}}
Supported values are auto, en, uk, pt-BR, de, es, cs, ru, fr, zh, it, ko, sv, ar and hu.
Chinese needs an installed CJK font, Arabic an installed Arabic font; Korean needs a font covering the Korean interface from the
optional craft-fonts input or the operating system. Without a suitable font, the saved choice is
retained and the result's shown is en. ui.set also accepts
{"interfaceLanguage":"uk"}; ui.inspect reports the saved choice in its UI state.
Invalid choices leave the current language unchanged. Menus, command labels and prompt text
returned by the control channel retain their English source text. See localization.md.