Tanish Manku 162cc4792b View twist: read and write every twist within one turn, so #2022's hostile-angle checks hold
A twist of -1e-20 degrees read as a full turn (2π), and a huge twist set from JSON or MCP was written as a huge angle. Readers and writers of VIEWPORT 51, VPORT 51 and VIEW 50 now go through norm_angle.